Technicial Specifications
| Standby Rating | 1750 ekW 1750 ekW | 
| Prime Power Rating | 1600 ekW 1600 ekW | 
| Emissions/Fuel Strategy | Low Fuel, Low Emissions Low Fuel, Low Emissions | 
| Voltage | 380 to 13800 Volts 380 to 13800 Volts | 
| Frequency | 60 Hz 60 Hz | 
| Speed | 1800 rpm 1800 rpm | 
| Duty Cycle | Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous | 
| Maximum Rating | 1750 ekW 1750 ekW | 
| Minimum Rating | 1450 ekW 1450 ekW | 
| Engine Model | 3516 TA, V-16, 4-Stroke Water-Cooled Diesel 3516 TA, V-16, 4-Stroke Water-Cooled Diesel | 
| Bore | 6.69 in 170 mm | 
| Stroke | 7.48 in 190 mm | 
| Displacement | 4210.64 in³ 69 l | 
| Compression Ratio | 13.0:1 13.0:1 | 
| Aspiration | TA TA | 
| Fuel System | Mechanical unit injection Mechanical unit injection | 
| Governor Type | Woodward Woodward | 
| Length - Minimum | 245.2 in 6228 mm | 
| Length - Maximum | 245 in 6228 mm | 
| Width - Minimum | 90 in 2286 mm | 
| Width - Maximum | 90 in 2286 mm | 
| Height - Minimum | 94.9 in 2410 mm | 
| Height - Maximum | 94.9 in 2410 mm | 
| Dry Weight - Genset (minimum) | 28840 lb 13080 kg | 
| Dry Weight - Genset (maximum) | 28840 lb 13080 kg | 
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- UL 2200 Listed
- CSA
- IBC seismic certification
- OSHPD pre-approval
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
- 
                        Air Inlet System
                        
                        - Air cleaner; single element canister type
 
- 
                        Control Panels
                        
                        
                        - Accessory module data link
 - Low coolant level
 - Environmental sealed front face
 - EMCP 4.2B
 - 6 Customer programmable digital inputs
 - Communications:
 - Load histogram feature
 - Overspeed
 - Alarm acknowledge
 - kW-hr (total)
 - 24 Volt DC operation
 - Over/under voltage (27/59)
 - 1 programmable relay outputs (Form C)
 - kVAr-hr (total)
 - Emergency stop pushbutton
 - PLC functionality
 - Speed adjust
 - Lamp test
 - Auto/start/stop control
 - Over/under frequency (81 o/u)
 - Generator phase sequence
 - Revers Power (kW) (32)
 - Oil pressure (psi, kPa or bar
 - Coolant temperature
 - RPM
 - Overcurrent (50/51)
 - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
 - Controls:
 - Number of I/O varies on options selected
 - Power factor (per phase & average)
 - 0 True RMS AC metering, 3-phase, +/-2% accuracy
 - kVA (per phase, average & percent)
 - Serial annunciator module data link
 - Customizable screens
 - Generator mounted - rear facing
 - kW (per phase, average & percent)
 - Text alarm/event descriptions
 - DC volts
 - Low oil pressure
 - Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
 - Reverse reactive power (kVAr) (32RV
 - Frequency (Hz)
 - Low coolant temperature
 - 3 Analog inputs
 - Cat connect
 - kVAr (per phase, average & percent)
 - Warning/shutdown with common LED indication of shutdowns for:
 - Engine cycle crank
 - Failure to start (overcrank)
 - Programmable protective relaying functions:
 - Emergency stop
 - Customer data link (Modbus RTU
 - Engine cool-down timer
 - Volts (L-L & L-N)
 - Amps (per phase & average)
 - Operating hours
 - High coolant temperature
 - Digital indication for:
 - 1 programmable digital outputs
 - 4 programmable relay outputs (Form A)
 
- 
                        Cooling System
                        
                        - Certified standard PGS provided
 
- 
                        Exhaust System
                        
                        
                        - Flanged faced outlet(s)
 - Dry exhaust manifold
 
- 
                        Fuel System
                        
                        
                        - Secondary fuel filters
 - Fuel cooler; not included with packages without radiator
 - Flexible fuel lines - shipped loose
 - Fuel priming pump
 
- 
                        General
                        
                        
                        - Right hand servicing
 - Flywheel and flywheel housing - SAE No. 00
 - SAE standard rotation
 
- 
                        Generator and Attachments
                        
                        
                        - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
 - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
 - Winding temperature detectors
 - Winding temperature detectors
 - Permanent magnet excitation (PMG)
 - Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
 - Six lead
 - Permanent magnet excitation (PMG)
 - Internal excitation (IE)
 - 3 Phase brushless, Salient pole
 - Winding temperature detectors
 - Medium voltage:
 - Random wound
 - Anti-condensation space heater
 - Low voltage:
 - High voltage:
 - Busbar connections, top center mounted, top cable entry
 - Form wound
 - Busbar connections, right side extension box, bottom cable entry
 - Form wound
 - NEMA standard hole pattern
 - NEMA standard hole pattern
 
- 
                        Governing System
                        
                        - ADEM A3
 
- 
                        Literature
                        
                        - Parts book
 
- 
                        Lubrication System
                        
                        
                        - Fumes disposal
 - Lubricating oil
 - Gear type lube oil pump
 - Oil filter, filler and dipstick
 - Oil drain lines and valve
 - Integral lube oil cool
 
- 
                        Mounting System
                        
                        
                        - Rails - engine/generator/radiator mounting
 - Anti-vibration mounts (shipped loose)
 - Rubber anti-vibration mounts - shipped loose
 
- 
                        Starting System
                        
                        
                        - Battery and battery rack w/cables
 - 45 Amp Charging alternator
 - Battery disconnect switch
 - 24 Volt electric starting motor
 
Optional Equipment
- 
                        Control System
                        
                        
                        - Controller: EMCP 4.2B
 - Local annunciator module: [ ] NFPA 110 [ ] Custom
 
- 
                        Air Inlet System
                        
                        
                        - Dual element air cleaner
 - Single element filter
 
- 
                        Cooling System
                        
                        
                        - Standard ambient radiators
 - Coolant
 - Optional installed ATAAC radiators
 - Optional installed radiators
 - Water level switch gauges
 - Standard ambient ATAAC radiators
 
- 
                        Engine Options
                        
                        
                        - Starting motors: [ ] Standard [ ] Heavy duty
 - Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
 - Starting aids: [ ] 220V 50 Hz Jacket water heater
 - Battery charger: [ ] 10A [ ] 20A [ ] 35A
 - Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
 - Muffler: [ ] Industrial Grade
 
- 
                        Crankcase System
                        
                        
                        - No explosion relief valves
 - Ventilation system
 - Explosion relief valves
 
- 
                        Alternators
                        
                        - Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
 
- 
                        Exhaust System
                        
                        
                        - Y Adapters
 - Tier 4 clean emissions module
 - Tier 4 dosing cabinet
 - Elbows
 - Tier 4 clean emission MOD Kits
 - Exhaust offset
 - Flanges
 - Flange and exhaust expanders
 - Flexible fittings
 - Mufflers
 - Clean emission parts
 
- 
                        Fuel System
                        
                        
                        - Fuel priming pumps (Tier 4) - Manual or electric
 - Primary fuel filter
 
- 
                        General
                        
                        
                        - US aid emblem
 - Special paint (Colors other than Caterpillar yellow or high performance paints)
 - The following options are based on regional and product configuration:
 - UL 2200 package
 - Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
 
- 
                        Generators and Attachments
                        
                        
                        - High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
 - Generator conversion
 - Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
 - Thermostat for space heater
 - Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
 - Alternator air cleaner
 - Differential current transformers (DCT)
 - High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
 - Differential current transformers (DCT) 8.7 kV and 15 kV classes
 - Space heater kit
 
- 
                        Power Termination
                        
                        
                        - Circuit breaker operation: [ ] Electrical
 - Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
 - Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
 - Power termination: [ ] Busbar [ ] Circuit breaker
 
- 
                        Extended Service Contract (ESC)
                        
                        - Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
 
- 
                        Instrumentation
                        
                        - Pyrometer and Thermocouples
 
- 
                        Lubrication System
                        
                        
                        - Lube oil in standard sump
 - Prelube pumps
 - Oil level regulator
 
- 
                        Mounting System
                        
                        
                        - Puck style low efficiency isolators
 - Spring type vibration isolators
 - IBC vibration isolators
 
- 
                        Power Connections
                        
                        
                        - Ground cables between generator and terminal box
 - Neutral ground connections
 - 2700 Frame, four lead, four terminal
 - Rear power connections
 - Right side power connections
 - Left side power connections
 - Low voltage Circuit breakers
 - Center post busbars
 
- 
                        Special Tests / Reports
                        
                        
                        - Generator test report
 - OSHPD Certification
 - Canadian Standards Association certification
 - PGS Test report @ 1.0 power factor
 - IBC Certification
 - Fuel consumption test
 - Generator set fuel consumption test
 - PGS Test report @ 0.8 power factor
 - Standard engine test charge
 - Torsional vibration analysis reports
 
- 
                        Starting and Charging
                        
                        
                        - Electric starting motors
 - Air pressure regulator
 - Starter cover
 - Air starting motors
 - 24 Volt battery set - Dry
 - 10, 20, 35 and 50 Amp Battery chargers
 - Jacket water heaters
 - Engine barring device
 
- 
                        Extended Service Coverage
                        
                        - Platinum, Gold and Silver coverage
 